Thyristor (thyristor) module instructions for use:

First, the use of conditions and precautions:

1, the use of the environment should be no severe vibration and impact, the environmental media should be no corrosion of metal and damage the insulation impurities and atmosphere.

2. Module junction working temperature: SCR is -40°C∽125°C; ambient temperature must not be higher than 40°C; ambient humidity is less than 86%.

3, the module must be equipped with a radiator before use, radiator selection see next section. Cooling can be natural cooling, forced air cooling or water cooling. When forced to cool, the wind speed should be greater than 6 m⁄seconds.

Second, installation precautions:

1. Because the MTC Thyristor Module is insulated (that is, the insulation voltage between the module terminals and the copper backplane is greater than 2.5KV effective value), it is possible to install multiple modules on the same heat sink or the grounding device of the device. on.

2. The surface of the radiator should be flat and smooth, with no scratches, bumps or debris. Radiator surface finish should be less than 10μm.

When the modules are mounted on the heat sink, a thin layer of thermal grease should be applied between their contact surfaces. Before applying grease, remove the oxide layer on the contact surface of the radiator with fine sandpaper, then wipe the surface clean with absolute ethanol to make the contact well so as to reduce the thermal resistance.

When the module is fastened to the surface of the heat sink, use M5 or M6 screws and spring washers, and tighten the screws with 4NM moments

The connection with the main electrode of the module should use copper strips, and have a smooth and flat contact surface, so that the contact is good. After 3 hours of module operation, each screw must be tightened again.

Module heat sink selection

When users choose the heat sink, they must consider the following factors:

1 Module operating current size to determine the required cooling area;

2 The use environment, according to which you can determine what cooling method to take - natural cooling, forced air cooling, or water cooling;

3 The shape and volume of the device and the size of the space reserved for the heat sink can be used to determine the shape of the heat sink.

In general, most users will choose aluminum radiators. For the convenience of users, the required heat dissipation area is given in the characteristic parameter table for all types of modules produced by our company. This area is a reference value when the module is operating at full capacity and forced air cooling.

The following formula is given for the length of the radiator:

The required cooling area of the module = (radiator circumference) × (radiator length) + (cross-sectional area) × 2

Among them, the required cooling area of the module is the reference value given in the characteristic parameter table of the module. The perimeter and cross-sectional area of the radiator can be found in the radiator manufacturer's sample, and the length of the radiator is the quantity to be obtained.

Contact Us

Author:

Mr. John chang

E-mail:

info@yzpst.com

Phone/WhatsApp:

8613805278321

Popular Products
You may also like
Related Information
Thyristor

The full name thyratron, commonly known as thyristor, is a bistable power electronic device that contains 3 or more PN junctions that can switch from off-state to on-state or from on-state to...

Judgment of thyristor damage causes

When the thyristor damage need to check the analysis of the reasons, the core can be removed from the cooling jacket, open the core box and then remove the chip, observe the signs of damage to...

Radiator thermal resistance, thyristor dissipated power test method

A special sealing device is made by the method of disposing the dust in the radiator. This kind of device only leaves the fan through hole. Go to the construction site and construction site to...

Talking about the method of thyristor overcurrent protection

In order to prevent damage to the thyristor caused by the failure of the AC circuit inversion of the thyristor, the traditional method is to use a fast fuse for overcurrent protection. The advantage...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

Contact Us

Author:

Mr. John chang

E-mail:

info@yzpst.com

Phone/WhatsApp:

8613805278321

Popular Products
Blog News
Thyristor

August 14, 2023

Home

Product

Whatsapp

About Us

Inquiry

苏ICP备05018286号-1
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send