Principle and difference of high power UPS 6-pulse and 12-pulse thyristor rectifiers
This paper elaborates the principle and difference of 6-pulse and 12-pulse rectifiers from four aspects: theoretical derivation, measured data analysis, harmonic analysis, improvement countermeasures and performance comparison. An in-depth analysis of the rectification technology of high power UPS.
Theoretical derivation
1,6 pulse rectifier principle:
6 Pulse refers to the full-bridge rectification consisting of 6 thyristors (thyristors). Because there are 6 switching pulses to control the 6 thyristors, it is called 6-pulse rectification.
When ignoring the commutation process and current pulsation of the three-phase bridge thyristor rectifier circuit, assuming that the AC side reactance is zero, the DC inductance is infinite, and the delay firing angle a is zero, the AC side current Fourier series is expanded to:
From the formula (1-1), the following conclusions can be drawn:
The current contains 6K?1 (k is a positive integer) subharmonic, that is, 5, 7, 11, 13... and other harmonics, the effective value of each harmonic is inversely proportional to the harmonic order, and The ratio of the effective value of the wave is the reciprocal of the harmonic order.
The above is part of the content, see the PDF document for more details!
August 12, 2024
The full name thyratron, commonly known as thyristor, is a bistable power electronic device that contains 3 or more PN junctions that can switch from off-state to on-state or from on-state to...
When the thyristor damage need to check the analysis of the reasons, the core can be removed from the cooling jacket, open the core box and then remove the chip, observe the signs of damage to...
A special sealing device is made by the method of disposing the dust in the radiator. This kind of device only leaves the fan through hole. Go to the construction site and construction site to...
In order to prevent damage to the thyristor caused by the failure of the AC circuit inversion of the thyristor, the traditional method is to use a fast fuse for overcurrent protection. The advantage...
Email to this supplier
August 12, 2024
August 14, 2023
January 07, 2021
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.